Antec ScientificElectrochemical Detectors

At Verulam Scientific, we are the UK distributor and authorised service partner for Antec Scientific, who have been the world-leading supplier of analytical instrumentation based on electrochemistry (EC) for more than 30 years. Use the link below to contact a member of our team and discuss your requirements today.

Superior Electrochemical Detectors from Antec Scientific

Below are two of the DECADE instruments from Antec Scientific, boasting highly sensitive electrochemical detection, compatible with any HPLC system.

DECADE Elite

The DECADE Elite is a highly sensitive electrochemical detector in HPLC applications, compatible with any third-party HPLC and UHPLC system, including Thermo Fisher Scientific, Agilent, and Shimadzu. It features a temperature-stabilised cell/column compartment and an Advanced Digital Filter (ADF) to improve the signal-to-noise ratio by up to 200 times. The DECADE Elite also offers different flow cells for optimal performance and is a suitable replacement for older ESA Coulochem II & III detectors, ensuring seamless method transfer and improved sensitivity. Its high-frequency data rate and proprietary SenCell™ make it compatible with UHPLC, capillary, and nano-LC.

https://verulamscientific.com/wp-content/uploads/2025/06/Decade-487.jpg
https://verulamscientific.com/wp-content/uploads/2024/02/DECADE_Elite2x-.jpg

DECADE Lite

The DECADE Lite boasts the same impressive performance as the Elite model, with superior ADF and temperature stability. There are a few differences between these models; the DECADE Lite has no keyboard and is controlled by free PC software. There is also the control for only one flow cell, and has DC measurement mode only. Discuss your requirements with a member of our team to ensure the instrument you choose will have maximum impact for your system.

DECADE Elite Vs DECADE Lite Features

 

Feature

DECADE Elite DECADE Lite

Sensitivity

Most sensitive electrochemical detector

Same core performance, but less flexible configuration

HPLC Compatibility

Compatible with all HPLC, UHPLC, capillary & nano-LC systems (e.g., Agilent, Thermo, Shimadzu)

Compatible with all HPLC, UHPLC, capillary & nano-LC systems (e.g., Agilent, Thermo, Shimadzu)

Temperature Stability

Temperature-stabilised cell and column compartment

Same temperature-stabilised performance

Signal-to-Noise Optimisation (ADF)

Advanced Digital Filter (ADF) improves S/N ratio by up to 200×

Same ADF performance

Flow Cell Support

Supports multiple flow cells for optimal performance

Supports only one flow cell at a time

Display/Controls

Front panel keyboard and display + software control

No keyboard/display; PC software control only

Electrochemical Modes

Multiple modes (including DC and pulse techniques)

DC mode only

Software Drivers

Full integration with CDS software (Clarity™, Chromeleon™, Empower™, OpenLab™, etc.)

Same software compatibility

SenCell™ Compatibility Compatible with all Antec flow cells

Compatible with all Antec flow cells

Control Software Full-featured Dialogue Elite software

Full-featured Dialogue Elite software

ALEXYS™ Analysers

The ALEXYS™ Analyser is a high-sensitivity UHPLC system with electrochemical detection, using a data management system that integrates with Clarity™ or Chromeleon™ CDS. This modular system includes an eluent tray, (U)HPLC pump, autosampler, column thermostat, and electrochemical detector. Modules are application-specific, optimising performance, usability, and cost. Antec Scientific offers a range of specialised Analysers, including:

Why Choose Verulam Scientific?

At Verulam Scientific, we are proud to be the UK distributors for a number of highly reputable US and European manufacturers. We’ve been delivering reliable, bespoke and innovative solutions to customers throughout the UK since 2009, supported by a carefully curated team of highly qualified industry professionals. We will tailor our solutions to meet your specific needs, whether you require an individual module or complete systems or workcells. Simply get in touch using the link below to learn more.

What Do Our Customers Say?

Still unsure? Why not take a look at what some of our previous clients have to say about a partnership with Verulam Scientific? We have successfully delivered high-quality instruments and bespoke packages for institutions across the UK. Click the link below to find out more about how we operate.

FAQs

How Sensitive Are Electrochemical Detectors in Detecting Analytes?

Liquid chromatography, such as HPLC or UHPLC with electrochemical detection, is a far more selective and sensitive approach when compared to most other detection techniques.

What Role Do Electrodes Play in Electrochemical Detection?

Electrodes used in electrochemical sensors ensure that target analytes undergo a redox (reduction-oxidation) reaction, causing electrons to be transferred. This transfer of electrons produces an electrical signal, proportional to the concentration of the analyte. This concentration can then be measured and analysed.

What Applications are Electrochemical Detectors Typically Used For?

Typical applications for electrochemical detectors are:

  • For the analysis of monoamines such as serotonin, dopamine, noradrenaline and their acidic metabolites.
  • The analysis of aminoglycosides and macrolide antibiotics in pharmaceutical formulations and bulk products.
  • For the analysis of carbohydrates in food, beverages, plants, and more.
  • For the quantitative analysis of the catecholamines norepinephrine, epinephrine, and dopamine in urine and plasma.
  • Plus many more